| RUBBER
CABLES |
|
Type Designation | Rated
Voltage | Conductors | Construction |
| Number | Sectional
(mm2) |
 |
| Designation - H01N2-D |
100 V | 1 |
10 to 185 |
- Flexible copper conductor /class 6/
- Separator
- Polychloroprene
sheath
|
| Standard
- VDE 0282 part 6 |
| Type
- Welding cable |
 |
| Application and Remarks:
In dry, damp and wet locations and outdoors. For very high mechanical stresses
as machine and hand welding cables. |
 |
| Designation - H05RN-F |
300/300
V | 1 2 3 4 5 |
0.75 and 1 0.75 and 1 0.75 and 1 0.75 0.75 |
- Flexible copper conductor tinned
- EPR insulation
- Polychloroprene
sheath
|
| Standard
- VDE 0282 part 4 |
| Type
- Ordinary polychloroprene rubber - sheathed cable |
 |
| Application
and Remarks: In dry, and wet locations and outdoors.For connecting electrical
appliances and tools with low mechanical stresses. |
| |
| Designation - H05RR-F |
300/500 V | 2 3 4 5 |
0.75 to 2.5 0.75 to 6 0.75 to 6 0.75 to 2.5 |
- Flexible copper conductor tinned
- EPR insulation
- EPR sheath
|
| Standard - VDE 0282 part 4 |
| Type - Ordinary tough rubber
- sheathed cord |
 |
| Application
and Remarks: In dry, location /homes, kitchens, office.For connecting electrical
appliances with low mechanical stresses. |
| |
| Designation - H07RN-F |
450/750 V | 1 2 3 4 5 6
to 18 19 to 36 |
1.5 to 240 1.0 to 25 1.0 to 95 1.0 to 95 1.0 to 25 1.5 to 4 1.5
to 2.5 |
- Flexible copper conductor tinned
- EPR insulation
- Synthetic
elastomer inner sheath /in some cases/
- Polychloroprene outer sheath
|
| Standard - VDE 0282 part 4 |
| Type - Ordinary polychloroprene
rubber - sheathed cable |
 |
| Application and Remarks:
In dry, damp and wet locations and outdoors. In agricultural operating areas and
those subject to fire hazard. For connecting electrical appliances and tools,
including industrial equipment with medium mechanical stresses. |
| |
| Designation - MGCG |
0.6/1 kV | 1 2 3 4 5 7
to 24 |
1.5 to 120 1.5 to 25 1.0 to 120 1.0 to 95 1.0 to 2.5 1.5 |
- Stranded copper conductor tinned
- EPR insulation
- Inner
covering
- Separating foil
- Copper wire braid
- Polychloroprene
outher sheath
|
| Standard
- DIN 89 158, IEC 332-3 cat A |
| Type
- Power cable for special applications |
 |
| Application and Remarks:
Shipboard power cable for permanent installation in any room and below the upper
metal deck. The copper wire braid also as mechanical protection. For this purpose
both ends must be securely earthed by screws. |
| |
| Designation - MGG |
0.6/1 kV | 1 2 3 4 5 7
to 24 |
1.5 to 120 1.5 to 25 1.0 to 120 1.0 to 95 1.0 to 2.5 1.5 |
- Stranded copper conductor tinned
- EPR insulation
- Inner
covering
- Polychloroprene outher sheath
|
| Standard
- DIN 89 160, IEC 332-3 cat A |
| Type
- Power cable for special applications |
 |
| Application and Remarks:
Shipboard power cable for permanent installation in any room and below the upper
metal deck. |
| |
| Designation - NTSCGEWou |
6/10 kV | 3 |
25 to 150 |
- Stranded copper conductor tinned
- Extruder, rubber based semiconductive
screen over conductor
- EPR insulation
- Extruded, rubber based semiconductive
screen insulation
- Extruded, rubber based semiconductive inner sheath
- Polychloroprene
outher sheath
|
| Standard
- VDE 0250 part 813 |
| Type
- Trailing cable |
 |
| Application and Remarks:
In dry, wet and moist locations with an associated explosion hazard, at building
sites, in industrial workshops, open face mining, in quarries and others. In power
supplies for connecting large equipment witch may be moved, for extremely high
mechanical loads such as excavators, loading bridges, portal cranes, construction
equipment as well as for supplying power to heavy duty hosting equipment, transport
and conveyor systems, power supplies for building, bridging mains network sections
in cases of power failure and for similar applications. |