| LOW VOLTAGE POWER CABLES
|
|
Type Designation
|
Rated
Voltage |
Conductors |
Construction |
| Number |
Sectional (mm2)
|
 |
| Designation - NYCY /power
cable/ |
0.6/1 kV
|
1
to 5
and other |
1.5 to 240
and other
|
- Solid or stranded copper conductors
- PVC insulation
- Extruded or taped filler
- Concentric conductor - copper wires
- PVC sheath
|
| Standard - IEC 502 |
| Type - Low voltage
power cables with PVC insulation and concentric protective conductor |
 |
| Application and Remarks: Indoors,
cable trunking, outdoors and buried in the ground, for power stations,
industry and switchgear, as well as for urban supply networks, if mechanical
damage is unlikely. Also available cables with fire retardant compounds
for insulation and sheath. This acomplishment of cables may cover requirements
of IEC 332-3 - Tests on electrical cables under fire condition. |
 |
| Designation - NYM-j |
0.3/0.5 kV
|
1
2 3 4 5 |
1.5-16 1.5-10 1.5-10
1.5-35 1.5-16
|
- Flexible copper conductor
- Extruded filer
- PVC insulation
- PVC seath
|
| Standard - VDE 0250 |
| Type - Light
PVC sheathed cable |
 |
| Application and Remarks:
On, in under plaster. |
 |
| Designation - AYBY /power
cable/ |
0.6/1 kV
|
1
2
3
4
5
and other |
25 to 500
25 to 240
25 to 240
25 to 240
25 to 95
|
- Solid or stranded alluminium conductors
- PVC insulation
- Extruded or taped bedding
- Steel tapes armour
- PVC sheath
|
| Standard -
IEC 502 |
| Type - Low voltage
power cables with PVC insulation |
 |
| Application and Remarks: Indoors,
cable trunking, outdoors and buried in the ground, for power stations,
industry and switchgear, as well as for urban supply networks. Also available
cables with fire retardant compounds for insulation bedding and sheath.
This acomplishment of cables may cover requirements of IEC 332 - Tests
on electrical cables under fire condition -Part 3: Tests on bunched wires
or cables. |
 |
| Designation - NACY |
0.6/1 kV
|
3
3+1 4 |
25-240
|
- Solid or stranded aluminum conductor
- PVC insulation
- Extruded filer
- Concentric conductor-copper wires
- PVC sheath
|
| Standard -
VDE 0271 |
| Type - Power
cables with PVC insulation and sheath with concentric protective conductor |
 |
| Application and Remarks:
Indoors, cable trunking, outdoors and buried in the ground, for power
stations, industry and switchgear, as well as for urban supply networks,
if mechanical damage is unlikely |
 |
| Designation - NAYY /power
cable/ |
0.6/1 kV
|
1
2
3
4
5
and other |
25 to 500
25 to 240
25 to 240
25 to 240
25 to 95
|
- Solid or stranded copper conductors
- PVC insulation
- Extruded or taped filler
- PVC sheath
|
| Standard -
VDE 0276 part 603, also IEC |
| Type -
Low voltage power cables with PVC insulation and sheath |
 |
| Application and Remarks:
Indoors, cable trunking, outdoors and buried in the ground, for power
stations, industry and switchgear, as well as for urban supply networks,
if mechanical damage is unlikely. Also available cables with fire retardant
compounds for insulation and sheath. This acomplishment of cables may
cover requirements of IEC 332-3 - Tests on electrical cables under fire
condition. |
 |
| Designation - NYY /power cable/ |
0.6/1 kV
|
1
2
3
4
5
and other |
1.5 to 500
1.5 to 240
1.5 to 240
1.5 to 240
1.5 to 25
|
- Solid or stranded copper conductors
- PVC insulation
- Extruded or taped filler
- PVC sheath
|
| Standard -
VDE 0276 part 603, also IEC |
| Type -
Low voltage power cables with PVC insulation and sheath |
 |
| Application and Remarks:
Indoors, cable trunking, outdoors and buried in the ground, for power
stations, industry and switchgear, as well as for urban supply networks,
if mechanical damage is unlikely. Also available cables with fire retardant
compounds for insulation and sheath. This acomplishment of cables may
cover requirements of IEC 332-3 - Tests on electrical cables under fire
condition. |
 |
| Designation - SAPEmT-et |
0.6/1kV-AC
3 kV -DC
|
1 |
240-500
|
- Stranded aluminium conductor
- PE insulation
- Metal screen-copper tape
- PVC sheath
|
| Standard -
BDS 2581-86 |
| Type -
Power cables with PE insulation and PVC sheath |
 |
| Application and Remarks:
The single-core cables are designed for transfer and distribution ofelectrical
power with nominal voltage AC - 0.6/1kV, 50Hz and DC - 3kV. Used in electrified
urban transport /trolley, tram, metro |
 |
| Designation - SPEmT-et |
0.6/1kV-AC
3 kV -DC
|
1 |
240-500
|
- Stranded copper conductor
- PE insulation
- Metal screen-copper tape
- PVC sheath
|
| Standard -
BDS 2581-86 |
| Type -
Power cables with PE insulation and PVC sheath |
 |
| Application and Remarks:
The single-core cables are designed for transfer and distribution ofelectrical
power with nominal voltage AC - 0.6/1kV, 50Hz and DC - 3kV. Used in electrified
urban transport /trolley, tram, metro |
 |
| Designation - YBY /power cable/ |
0.6/1 kV
|
1
2
3
4
5
7 to 19
20 to 37
and other |
1.5 to 500
1.5 to 240
1.5 to 240
1.5 to 240
1.5 to 25
1.5, 2.5, 4
1.5, 2.5
|
- Solid or stranded copper conductors
- PVC insulation
- Extruded or taped bedding
- Steel tapes armour
- PVC sheath
|
| Standard -
IEC 502 |
| Type -
Low voltage power cables with PVC insulation |
 |
| Application and Remarks:
Indoors, cable trunking, outdoors and buried in the ground, for power
stations, industry and switchgear, as well as for urban supply networks.
Also available cables with fire retardant compounds for insulation bedding
and sheath. This acomplishment of cables may cover requirements of IEC
332 - Tests on electrical cables under fire condition -Part 3: Tests on
bunched wires or cables. |
 |
| Designation - N2XY |
0.6/1 kV
|
1
4
|
16 to 500
16 to 185
|
- Cu solid or stranded class 1 or 2
- Insulation of XLPE type DIX3
- Cores twisted concentrically
- Elastic or plastic filling compound sheath compound of PVC type
DMV
|
Standard -
VDE 0276-603,
IEC 60502-1 |
| Type -
Cables with Cu wires, XLPE insulation and PVC sheaths |
 |
| Application and Remarks:
The power cables with indulation of cross-linked polyethylene /XLPE/ are
designed for distribution and supply of consumers with normal voltage
0.6/1kV and frequency 50Hz in industrial installations and urban networks.
They are suitable for fixed indoor assembly in cable ducth and conduits,
over shelves and grilles, directly underground in ditch and outdoor under
shelters providing the conditions determined for the type of cable. |
 |
| Designation - NA2XY |
0.6/1 kV
|
1
4
|
50 to 500
50 to 240
|
- Solid or stranded alluminium conductors
- XLPE insulation
- Extruded or tapes bedding
- PVC sheath
|
| Standard -
VDE 0276 part 603 |
| Type -
Low voltage power cables with XLPE insulation |
 |
| Application and Remarks:
Indoors, cables trunking, outdoors and buried direct in ground, for power
station, industry and switchgear, as well as for urban supply networks,
if mechanical damage is unlikely. Maximum conductor temperature - 90 C |