LOW VOLTAGE POWER CABLES

Type Designation

Rated
Voltage
Conductors Construction
Number Sectional (mm2)
Designation - NYCY /power cable/

0.6/1 kV

1 to 5
and other

1.5 to 240
and other

  • Solid or stranded copper conductors
  • PVC insulation
  • Extruded or taped filler
  • Concentric conductor - copper wires
  • PVC sheath
Standard - IEC 502
Type - Low voltage power cables with PVC insulation and concentric protective conductor
Application and Remarks: Indoors, cable trunking, outdoors and buried in the ground, for power stations, industry and switchgear, as well as for urban supply networks, if mechanical damage is unlikely. Also available cables with fire retardant compounds for insulation and sheath. This acomplishment of cables may cover requirements of IEC 332-3 - Tests on electrical cables under fire condition.
Designation - NYM-j

0.3/0.5 kV

1 2 3 4 5

1.5-16 1.5-10 1.5-10
1.5-35 1.5-16

  • Flexible copper conductor
  • Extruded filer
  • PVC insulation
  • PVC seath
Standard - VDE 0250
Type - Light PVC sheathed cable
Application and Remarks: On, in under plaster.
Designation - AYBY /power cable/

0.6/1 kV

1
2
3
4
5
 and  other

25 to 500
25 to 240
25 to 240
25 to 240
25 to 95

  • Solid or stranded alluminium conductors
  • PVC insulation
  • Extruded or taped bedding
  • Steel tapes armour
  • PVC sheath
Standard - IEC 502
Type - Low voltage power cables with PVC insulation
Application and Remarks: Indoors, cable trunking, outdoors and buried in the ground, for power stations, industry and switchgear, as well as for urban supply networks. Also available cables with fire retardant compounds for insulation bedding and sheath. This acomplishment of cables may cover requirements of IEC 332 - Tests on electrical cables under fire condition -Part 3: Tests on bunched wires or cables.
Designation - NACY

0.6/1 kV

3 3+1 4

25-240

  • Solid or stranded aluminum conductor
  • PVC insulation
  • Extruded filer
  • Concentric conductor-copper wires
  • PVC sheath
Standard - VDE 0271
Type - Power cables with PVC insulation and sheath with concentric protective conductor
Application and Remarks: Indoors, cable trunking, outdoors and buried in the ground, for power stations, industry and switchgear, as well as for urban supply networks, if mechanical damage is unlikely
Designation - NAYY /power cable/

0.6/1 kV

1
2
3
4
5
 and  other

25 to 500
25 to 240
25 to 240
25 to 240
25 to 95

  • Solid or stranded copper conductors
  • PVC insulation
  • Extruded or taped filler
  • PVC sheath
Standard - VDE 0276 part 603, also IEC
Type - Low voltage power cables with PVC insulation and sheath
Application and Remarks: Indoors, cable trunking, outdoors and buried in the ground, for power stations, industry and switchgear, as well as for urban supply networks, if mechanical damage is unlikely. Also available cables with fire retardant compounds for insulation and sheath. This acomplishment of cables may cover requirements of IEC 332-3 - Tests on electrical cables under fire condition.
Designation - NYY /power cable/

0.6/1 kV

1
2
3
4
5
 and  other

1.5 to 500
1.5 to 240
1.5 to 240
1.5 to 240
1.5 to 25

  • Solid or stranded copper conductors
  • PVC insulation
  • Extruded or taped filler
  • PVC sheath
Standard - VDE 0276 part 603, also IEC
Type - Low voltage power cables with PVC insulation and sheath
Application and Remarks: Indoors, cable trunking, outdoors and buried in the ground, for power stations, industry and switchgear, as well as for urban supply networks, if mechanical damage is unlikely. Also available cables with fire retardant compounds for insulation and sheath. This acomplishment of cables may cover requirements of IEC 332-3 - Tests on electrical cables under fire condition.
Designation - SAPEmT-et

0.6/1kV-AC
3 kV -DC

1

240-500

  • Stranded aluminium conductor
  • PE insulation
  • Metal screen-copper tape
  • PVC sheath
Standard - BDS 2581-86
Type - Power cables with PE insulation and PVC sheath
Application and Remarks: The single-core cables are designed for transfer and distribution ofelectrical power with nominal voltage AC - 0.6/1kV, 50Hz and DC - 3kV. Used in electrified urban transport /trolley, tram, metro
Designation - SPEmT-et

0.6/1kV-AC
3 kV -DC

1

240-500

  • Stranded copper conductor
  • PE insulation
  • Metal screen-copper tape
  • PVC sheath
Standard - BDS 2581-86
Type - Power cables with PE insulation and PVC sheath
Application and Remarks: The single-core cables are designed for transfer and distribution ofelectrical power with nominal voltage AC - 0.6/1kV, 50Hz and DC - 3kV. Used in electrified urban transport /trolley, tram, metro
Designation - YBY /power cable/

0.6/1 kV

1
2
3
4
5
7 to 19
20 to 37
 and  other

1.5 to 500
1.5 to 240
1.5 to 240
1.5 to 240
1.5 to 25
1.5, 2.5, 4
1.5, 2.5

  • Solid or stranded copper conductors
  • PVC insulation
  • Extruded or taped bedding
  • Steel tapes armour
  • PVC sheath
Standard - IEC 502
Type - Low voltage power cables with PVC insulation
Application and Remarks: Indoors, cable trunking, outdoors and buried in the ground, for power stations, industry and switchgear, as well as for urban supply networks. Also available cables with fire retardant compounds for insulation bedding and sheath. This acomplishment of cables may cover requirements of IEC 332 - Tests on electrical cables under fire condition -Part 3: Tests on bunched wires or cables.
Designation - N2XY

0.6/1 kV

1
4

16 to 500
16 to 185

  • Cu solid or stranded class 1 or 2
  • Insulation of XLPE type DIX3
  • Cores twisted concentrically
  • Elastic or plastic filling compound sheath compound of PVC type DMV
Standard - VDE 0276-603,
IEC 60502-1
Type - Cables with Cu wires, XLPE insulation and PVC sheaths
Application and Remarks: The power cables with indulation of cross-linked polyethylene /XLPE/ are designed for distribution and supply of consumers with normal voltage 0.6/1kV and frequency 50Hz in industrial installations and urban networks. They are suitable for fixed indoor assembly in cable ducth and conduits, over shelves and grilles, directly underground in ditch and outdoor under shelters providing the conditions determined for the type of cable.
Designation - NA2XY

0.6/1 kV

1
4

50 to 500
50 to 240

  • Solid or stranded alluminium conductors
  • XLPE insulation
  • Extruded or tapes bedding
  • PVC sheath
Standard - VDE 0276 part 603
Type - Low voltage power cables with XLPE insulation
Application and Remarks: Indoors, cables trunking, outdoors and buried direct in ground, for power station, industry and switchgear, as well as for urban supply networks, if mechanical damage is unlikely. Maximum conductor temperature - 90 C